Specifications

Control Unit

casing glasfibre-reinforced polyester
protection class IP 66 (dust entry and occasional flooding)
sensor cables (max.) versions for 3, 15 and 30 cables available
sensors (max.) up to 1000 (standard version)
internal sensors 2 (internal unit temperature, external reference)
data memory {tip 512 kbyte data memory::sufficient for more than 5000 measuring cycles with 50 sensors}512 kbyte{/tip}
PC interface serial RS232 interface (COM port)
operating temperature -20 to +50°C
power supply 7.2 V NiMH battery (backed by a solar panel)
AC adapter input 100-240 V AC / 47-63 Hz, output 12 V DC / 1.25 A
size (W x D x H) 200 x 150 100 mm (without connection socket)
weight 2500 g

Sensor Cables

sensor measuring range -55 to +125°C (limited by cable operating temperature)
sensor accuracy ± 0.5°C (-10 to +85°C), ± 2.0°C (-55 to -10 and +85 to 125°C)
sensor resolution 0.0625°C
sensor spacing ≥ 10 cm, custom and irregular spacings possible
cable jacket polyurethan (standard version)
cable operating temperature -30 to + 85°C (standard version)
cable diameter ≤ 10 mm (standard version)
single cable length (max.) up to 350 m (standard version)
connectors IP 67 (splash-proof) or IP 68 (underwater version)

Software

operating system platform independent (Java Runtime Environment), support currently available for Windows 2000, XP and Win 7
CPU 200 MHz or better
RAM 64 MB minimum, 256 MB recommended
interface 1 x COM port RS232
screen resolution 1024 x 768 or better