Control Unit
casing | glasfibre-reinforced polyester |
protection class | IP 66 (dust entry and occasional flooding) |
sensor cables (max.) | versions for 3, 15 and 30 cables available |
sensors (max.) | up to 1000 (standard version) |
internal sensors | 2 (internal unit temperature, external reference) |
data memory | {tip 512 kbyte data memory::sufficient for more than 5000 measuring cycles with 50 sensors}512 kbyte{/tip} |
PC interface | serial RS232 interface (COM port) |
operating temperature | -20 to +50°C |
power supply | 7.2 V NiMH battery (backed by a solar panel) |
AC adapter | input 100-240 V AC / 47-63 Hz, output 12 V DC / 1.25 A |
size (W x D x H) | 200 x 150 100 mm (without connection socket) |
weight | 2500 g |
Sensor Cables
sensor measuring range | -55 to +125°C (limited by cable operating temperature) |
sensor accuracy | ± 0.5°C (-10 to +85°C), ± 2.0°C (-55 to -10 and +85 to 125°C) |
sensor resolution | 0.0625°C |
sensor spacing | ≥ 10 cm, custom and irregular spacings possible |
cable jacket | polyurethan (standard version) |
cable operating temperature | -30 to + 85°C (standard version) |
cable diameter | ≤ 10 mm (standard version) |
single cable length (max.) | up to 350 m (standard version) |
connectors | IP 67 (splash-proof) or IP 68 (underwater version) |
Software
operating system | platform independent (Java Runtime Environment), support currently available for Windows 2000, XP and Win 7 |
CPU | 200 MHz or better |
RAM | 64 MB minimum, 256 MB recommended |
interface | 1 x COM port RS232 |
screen resolution | 1024 x 768 or better |